A.B. Machine Inc.  


Home          Photos           Parts List          Specifications            Contact Us     

 
  

Flexo Guards©

Here is an easy to follow installation guide for the Flexo Guard© and Flexo Guard© Grain Saver Boots.

 

FLEXO GUARD INSTALLATION INSTRUCTIONS

CLASP INSTALLATION - 2  clasps are required per section, one on each side.  Place all Flexo Guard sections on guard points for reference.  Space clasps accordingly.  Remove guard point nut and place clasp in direction show per Figure A.  Secure using the same nut removed.  Besure nuts are drawn tight!  Clasp should be left in place from
season to season to facilitate subsequent installations.

figureA2.jpg - 26585 Bytes

CLIP INSTALLATION - From below, place both ends over adjacent Flexo Guard fingers centering the clip in front of the clasp previously nstalled.  Using a screwdriver, force the center of the clip toward the clasp using the guard point nut as leverage.  SeeFigure C for visual referenceA hammer may be needed to tap the clip down the shank of the
screwdriver toward the clasp.  Make sure clip is fastened securely in clasp hooks.

figureC2.jpg - 39104 Bytes

TINE WIRE INSTALLATION - With the Flexo Guard sections mounted firmly in place, compress the ends of the tine wires together and thread in to tine clip holes.  Take care not to cross tine wire ends or damage may occur!  Push the tine wire through the tine clip as far as possible using hand pressure.  When you have completed a section, use a block of wood and a hammer to tap them to their fully seated position as shown in Figure B.  This will also seat each section properly to better facilitate clip instalation.  If you are using bolt-on sickle sections you must put ABM Grain Saver Boots on either side of the sicke hold down to prevent tine wire damage.  (Hint: If you are using a bolt-on sickle section and do not have ABM Grain Boot Savers installed, bend the end of the tine wire down 45 degrees 3" inches from the end.  Do this on tine wires located on either side of sickle hold down.  This will detour the sickle bolts from grabing the tine wire but will not prevent it.)

figureB2.jpg - 46537 Bytes

REEL SET UP INSTRUCTIONS - The center line of your reel needs to be set 5" to 6" inches from the back of the Grain Saver Boot Attachment to allow proper feed action.  Also, it is recomended to leave the bat clearance between 2" to 3" inches from the top of the Grain Saver Boot Attachment.  See Figure D for visual reference.

figureD2.jpg - 18613 Bytes

 

 

ABM GRAIN SAVER BOOTS - The Grain Saver Boots are mad of UV Stabilized High Density Polyethylene material that is weather resistant, long wearing, and resists breakage in cold weather.  When first recieved, the Grain Saver Boots will be somewhat stiff.  To improve hinging action before the first field run, compress the sides together a few times by hand.  This will greatly improve flexibility for better initial stock feed to sickle and platform. 

For installation instructions see ABM Grain Saver Installation Section.  

For configuration instructions see Flexo Guard Configuration Instructions Section.